Home : Remanufactured Flowmeters : Flow Instrumentation Before and After Pictures

Before and After Pictures

 

 

 

more pictures

 

3" MicroMotion D Series meter was received from a major oilfield services company with clogged tubes.  The drilling cement was cleared from the tubes, the terminal block was replaced and the meter was calibrated traceable to NIST.

 

  

10" Foxboro Model 1800 was originally manufactured at factory in 1968.  It was remanufactured at TECO in 1989, and was recently returned to TECO for remanufacture in 2010 where the teflon liner, titanium electrodes and coils were replaced.  It was calibrated traceable to NIST and returned with TECO's standard 1 year warranty.

 

  

12" Rosemount Model 8701 was received from a major oil refinery in Texas.  The meter was remanufactured and calibrated traceable to NIST with a Rosemount 8712C converter.

 

  
 Rosemount Model 3051 Pressure Transmitter was received from a national paper mill.  We repaired and calibrated to factory specifications.  We repair/replace sensors, and install diaphrams of any material or size.  We repair filled capillary systems/ remote seal transmitters, single and dual.
 

 

 
 6" Fischer & Porter 10D1465 meter received from a major manufacturer of chlor alkaline with major blistering in the tefzel liner.  Meter was remanufactured to mint condition and flow calibrated traceable to NIST
 

 
 1" Krohne M940/6  meter was received from a premier global specialty chemical manufacturing company with shorted electrodes and coils and a torn urethane liner.  Meter was remanufactured with new: tube, teflon liner, coils and electrodes and was certified traceable to NIST
 

 
 4" Rosemount 8701 meter was received from a major manufacturer of corrugated products.  The teflon liner was torn and the electrodes were shorted.  Meter was remanufactured with new: tefon liner, electrodes and coils and was flow calibrated traceable to NIST.   Per the customer's request, SS grounding rings were added
  
 ElectriPower Actuator was received from an international oil well fracturing company.  We repair most major brands of valve actuators and valve positioners to like-new condition.
 
 
 10" Fischer & Porter 10D1416 meter was received from a global leader in the design and manufacture of floors and ceilings.  Meter was remanufacutured with new: neoprene liner, coils and electrodes.  Meer was flow calibrated traceable to NIST and even though the meter is an obsolete model, it ships with TECO's standard 1 year warranty.
 
 
 6" Foxboro Model 9306 meter with a PFA liner was received from a manufacturer of high quality newsprint and paperboard.  We switched the liner to teflon and replaced the coils and electrodes.  Meter was flow tested traceable to NIST and shipped with TECO's standard 1 year warranty.
  
 16" Krohne Model IFS4000 with neoprene liner was received from a company which services US DOE on SSR projects.  We switched the liner to tefzel, replaced the coils and installed new titanium electrodes.  Meter was flow calibrated traceable to NIST and shipped with TECO's standard 1 year warranty.
  
 12" Rosemount Model 8703 was received from a paper company with a bad liner, shorted coils and electrodes.  We installed a new teflon liner, coils and Hastelloy C electrodes.  Meter was flow calibrated traceable to NIST and shipped with our standard 1 year warranty
 
 
 3" E&H Coriolis Meter was sent to us from an oilfield services company.  The issue with the sensor was fairly obvious as you can see a boxcutter tool stuck in the clogged tube.  We cleared the blockage and repaired the meter to MINT condition before sending it to our calibration lab for a NIST traceable certificate.
 
 
 6" ABB Meter was received from an electrical company in need of our standard remanufacturing services.  We broke the meter down and replaced the teflon liner, coils and electrodes, and sent it out with a NIST traceable certificate and a 1 year warranty.
 
 
 Honeywell STF132-R1H Pressure Transmitter was received from a component repair company.  It had a bad diaphragm seal and loss of fill.  The transmitter was completely reconditioned and calibrated traceable to NIST.
 
 
 4" Rosemount Model 8701  This is an example of a customized solution we provided to our customer in the titanium mining industry.  We provided an off-the-shelf Rosemount 8701 meter and marryed with an integral 8732 converter.  The meter was calibrated traceable to NIST and carries our standard 1 year warranty as well.
  
 30" Krohne Model 63C was received from a dredging company.  We had converted the meter from a rubber liner to ceramic brink and the customer was delighted to have gotten 11 years of service in their toughest application.  We remanufactured the meter back to mint condition and sent it back with a NIST traceable certificate.
 
 
 6" Brooks Model 7500 was received from a chemical company located in Canada.  Even though this model was obsoleted by the OEM some time ago, and has 1500# flanges, a neoprene liner and Hastelloy C electrodes - NO problem for TECO!!  We remanufactured the meter back to mint condition and shipped it back with a NIST traceable certificate and our standard one year warranty, just like a new meter.
 
 
 3" MicroMotion Series D was received from a oil field services company.  They required that the meter be repaired and returned with the metal frame.  Need a customized solution?  No problem for TECO, we shipped the meter as requested with a NIST traceable certificate and our standard warranty.
 
 
 8" Foxboro Model 2800 came to us from a pulp & paper company after use in a pretty harsh application.  We knew this meter, as it has been coming to TECO for remanufacturing for over a decade.  When we saw it five years ago, we provided the same great service of restoration to mint condition, NIST traceable certification and one year warranty. 
 
 
 24" Krohne Model IFS4000 was received from an Oil & Gas Exploration Services company.  We removed the neoprene liner and replaced it with an ETFE liner.  We replaced the coils and titanium electrodes as part of our standard restoration services, then sent it back to the customer with a new 1 year warranty and NIST traceable certificate. 
 
 
 2" Neptune Model 832-1 Water Meter was received by a hardboard manufacturer.  We reconditioned the meter by repairing the register and replacing the soft goods. 
 
 
 20" Krohne Model IFS4000 was received from a nonferrous metals producer.  We changed the electrodes and coils as well as replaced their neoprene liner with a Linatex liner so they would keep in production longer, making money.  As always, our standard 1 year warranty and NIST traceable certificate applies.
 
 
 3" ABB Model FEP - was received from a customer in the mining industry.  It needed a new teflon liner, new 316SS electrodes, and coils.....A bread and butter meter for TECO.  We restored to mint condition and sent back to the customer with a NIST traceable certificate and our standard 1 year warranty.
  
6" Turbo Meter was received by a customer does industrial manufacturing.  We replaced the teflon liner and hastelloy C electrodes.  We also customized the meter by replacing the Turbo converter with a Rosemount 8712 converter because the customer was more familiar with this brand of secondary. 
  
 10" Rosemount Model 8705 was received from one of our large petrochemical customers.  We restored the meter to MINT conditon, replacing the teflon liner and stainless steel electrodes.  It was delivered within 21 days with our NIST traceable calibration certificate.